UVW-1200, 1400, 1600, 1800 error codes

Назад


 Структура кода:

Main code 0X : Servo system or tape path system problem

Main code 02 К началу страницы
Subcode Detection Operation after detection Valid mode Display
058 It is detected that the current of the S reel motor is not normal. AUTO OFF EJECT (Emergency EJECT) Displays until pressing any button or until inserting a cassette tape again.
078 It is detected that the current of the T reel motor is not normal.
154The S reel FG cannot be detected by FG check when inserting a cassette tape. Removes cassette tape automatically.  
174 The T reel FG cannot be detected by FG check when inserting a cassette tape.
 
194 Neither S reel FG nor T reel FG can be detected by FG check when inserting a cassette tape.
255 The S reel FG is detected in threading. AUTO OFF EJECT (Emergency EJECT)
274 The T reel FG cannot be detected in threading.
355 The S reel FG is detected in STOP or STILL mode.
375 The T reel FG is detected in STOP or STILL mode.
395 The S reel FG and T reel FG are detected in STOP or STILL mode.
402 It is detected that the tape does not run at the specified speed in F. FWD or REW mode. STOP Error is remedied, then the unit operates normally. Displays until pressing any button.
403 The slack of the tape is detected in F. FWD or REW mode. AUTO OFF EJECT (Emergency EJECT) Displays until pressing any button or until inserting a cassette tape again.
454 The S reel FG cannot be detected in F. FWD or REW mode.
474 The T reel FG cannot be detected in F. FWD or REW mode.
494 Neither S reel FG nor T reel FG can detected in F. FWD or REW mode.
496 It is detected that the rotations of S and T reel are not normal in F. FWD or REW mode.
503 The slack of the tape is detected in SEARCH mode.
554 The S reel FG cannot be detected in SEARCH mode.
574 The T reel FG cannot be detected in SEARCH mode.
594 Neither S reel FG nor T reel FG can be detected in SEARCH mode. AUTO OFF EJECT (Emergency EJECT) Displays until pressing any button or until inserting a cassette tape again.
596 It is detected that the rotations of S and T reel are not normal in SEARCH mode.
603 The slack of the tape is detected in PLAY or REC mode.
654 The S reel FG cannot be detected in PLAY or REC mode.
674 The T reel FG cannot be detected in PLAY or REC mode.
694 Neither S reel FG nor T reel FG can be detected in PLAY or REC mode.
696 It is detected that the rotations of S reel and T reel are not normal in PLAY or REC mode.
803 The slack of the tape is detected when unthreading.
855 The S reel FG is detected when unthreading.
874 The T reel FG cannot be detected when unthreading.
A55 The S reel FG is detected during removal of a cassette tape. Until the error is remedied, inhibits inserting a cassette tape.
A75 The T reel FG is detected during removal of a cassette tape.
A95 The S reel FG and T reel FG are detected during removal of a cassette tape.


Main code 06 К началу страницы
Subcode Detection Operation after detection Valid mode Display
6A7 It is detected that the tape tension is not normal in PLAY or REC mode. Continues operating in the mode in which the problem is detected. When enters other than PLAY or REC mode, AUTO OFF. The error is remedied,
then the unit operates normally.
In PLAY or REC mode : Continues operating. In other than PLAY or REC mode: STOP, then EJECT (emergency EJECT)
Displays until the error is remedied and pressing any button.


Main code 07 К началу страницы
Subcode Detection Operation after detection Valid mode Display
042 It is detected that the speed of the capstan is not normal. STOP The error is remedied, then the unit operates normally. Displays until pressing any button.
144 The capstan FG cannot be detected by FG check when inserting a cassette tape. Removes cassette tape automatically.   Displays until inserting a cassette tape again.


Main code 08 К началу страницы
Subcode Detection Operation after detection Valid mode Display
03A It is detected that the speed of the drum is not normal. RETRY (Once unthreading, then threading again.) EJECT Displays until the error is remedied.
032 The drum speed problem is not remedied. AUTO OFF EJECT Displays until inserting a cassette tape again.


Main code 09 К началу страницы
Subcode Detection Operation after detection Valid mode Display
028 It is detected that the current of the threading motor is not normal. AUTO OFF EJECT (Emergency EJECT) Displays until pressing any button or until inserting a cassette tape again.
209 When detects full top or end of a tape in the threading state and then performs SHORT FF/SHORT REW, top or end is not released. Removes cassette tape automatically.  
221 Threading is not completed within the specified time. AUTO OFF EJECT (Emergency EJECT)
821 Unthreading is not completed within the specified time.


Main code 2X : Mechanical control system problem

Main code 20 К началу страницы
Subcode Detection Operation after detection Valid mode Display
018 It is detected that the current of the cassette up/down motor is not normal. AUTO OFF EJECT (Emergency EJECT) Displays until pressing any button or until inserting a cassette tape again.
111 The operation of cassette down is not completed within the specified time. Removes cassette tape automatically.  
911 The operation of cassette up is not completed within the specified time. AUTO OFF Inhibits all modes.


Main code 21 К началу страницы
Subcode Detection Operation after detection Valid mode Display
OC8 It is detected that the current of the reel position motor is not normal. AUTO OFF EJECT (Emergency EJECT) Displays until pressing any button or until inserting a cassette tape again.
1C1 The driving of the reel position is not completed within the specified time. Removes cassette tape automatically.  


Main code 3X : Sensors problem

К началу страницы
The sub code of the main code 3X is 000
Main code Detection Operation after detection Valid mode Display
30 Tape-top and tape-end are detected at the same time. STOP PLAY, EJECT Displays until an error is clear up.
31 Tape-top is not released. STOP PLAY, FF, EJECT
32 Tape-end is not released. STOP PLAY, REW, EJECT
33 The reel position sensor detects the L position and S position at the same time. Inhibits inserting a cassette tape.  


Main code 9X : Communication and interface systems problem

К началу страницы
Main code Subcode Detection
91 125 The interface problem between system control and keyboard is detected.
138 Problem on the hours meter data of EEPROM is detected.
145 The initialization problem between system control and servo is detected.
165 The interface problem between system control and TBC is detected.
436 Problem on the servo adjustment data of EEPROM is detected.
455 The interface problem between main servo and sub servo is detected.
92 000 1/2 YD signal with input to system control cannot be detected.
93 000 Servo reference sync signal cannot be detected.
94 000 Servo input sync signal cannot be detected.

Назад